U-20XD Series
Specifications
The Importance of Measurement Items in the Monitoring of Water Pollution in Lakes and Marshes

Water Quality Monitoring System
U-20XD Series

Specifications
 
U-22XD SET
W-22XD
W-23XD
Control Unit
Water proof construction
IP-67
( )
option
( )
option
Multi-Probe *1
Measurement temperature
0~55°C
(to30m)
Storage temperature
-5~60°C
Measurement depth *2
to 100 m
Maximum probe size
95 mm
Probe length
430 mm
Continuous use *3
30days
Data logging
Manual data memory (2880 items)
Automatic calibration
pH
*Two-point calibration
*Automatic temperature compensation
Measurment Principle
Glass electrode method
( )
option
( )
option
Range
pH 0~14
Resolution
0.01 pH
Repeatability
±0.05 pH
Accuracy
±0.1 pH
Dissolved oxygen
*Salt correction
(0 to 40 ppt /automatic)
*Automatic temperature compensation
Measurment Principle
Diaphragm galvanic battery method
( )
option
( )
option
Range
0~19.99 mg/L
Resolution
0.01 mg/L
Repeatability
±0.1 mg/L
Accuracy
±0.2 mg/L
Conductivity
*Auto range
*Automatic temperature
conversion (25°C)
*SI units
Measurment Principle
4 AC electrode method
Range
0~9.99 S/m
Resolution
0.1%F.S
Repeatability
±1%
Accuracy
±3%
Salinity
Measurment Principle
Conductivity conversion
Range
0~4%
Resolution
0.01%
Repeatability
±0.1%
Accuracy
±0.3%
Total Dissolved Solids (TDS)
*Conversion factor setting
Measurment Principle
Conductivity conversion
Range
0~100 g/L
Resolution
0.1%F.S
Repeatability
±2 g/L
Accuracy
±5 g/L
Seawater specific gravity
*Display t, 0, 15
Measurment Principle
Conductivity conversion
Range
0~50 t
Resolution
0.1 t
Repeatability
±2 t
Accuracy
±5 t
Temperature
Measurment Principle
Thermistor method
Range
0~55°C
Resolution
0.01°C
Repeatability
±0.3°C
Accuracy
±1.0°C
Turbidity
*Unit selection
Measurment Principle
Penetration and scattering method
Range
0~800 NTU
Resolution
0.1 NTU
Repeatability
±3%
Accuracy
±5%
Water depth
Measurment Principle
Pressure method
Range(NTU or mg/L)
0~100m
Resolution
0.1 m
Repeatability
±3%
Accuracy
±5%
Oxidation reduction potential(ORP)
Measurment Principle
Platinum electrode method
( )
option
( )
option
Range
±1999 mV
Resolution
1 mV
Repeatability
±5 mV
Accuracy
±15 mV
Ion
*Auto range
Measurment Principle
Ion electrode method
-
-
( )
option
( )
option
( )
option
Resolution
0.1%F.S
Repeatability
±5%
Accuracy
±10%
Nitric acid ion
Range
NO3-: 0.62~62,000 mg/L(pH 3~7)
Chloride ion
Cl-: 0.4~35,000 mg/L(pH 3~11)
Calcium ion
Ca2+: 0.4~40,080 mg/L(pH 5~11)
Fluoride ion
F-: 0.02~19,000 mg/L(pH4~10:20 mg/L)
Potassium ion
K+: 0.04~39,000 mg/L(pH5~11:3.9 mg/L)
Ammonia
NH3: 0.1~1,000 mg/L(pH 12 or more)
Simultaneously measurable parameters
   
10
10
13

Note: The accuracy rating value is obtained from measurements at an intermediate point of the standard solution after two-point calibration (at room temperature and pressure).
The repeatability and accuracy rating percentages are based on the full scale (except for salinity).
*1: Organic solvents, strong acids, and strong alkaline solvents cannot be measured.
*2: The maximum depth for ion measurements are 100 m for nitric acid ion, chioride ion, fluoride ion, 15 m for calcium ion, ammonia, and 3 m for potassium ion.
*3: Based on the data measured automatically at 15 minutes intervals. The battery life taken into account.
Periodical maintenance and calibration is necessary when a lot of shellfishes and seaweeds exist at the measurement point.


TOP
Copyright (C) 2008 HORIBA, Ltd. All rights reserved.

Copyright © 2008 HORIBA, Ltd. All rights reserved. The information shown on this document may be modified without notice. Refer to the original web page for update. The page was copied from:
 