Specifications
Model
CS-137
CS-137-2503
CS-137-1003
Measurement sample
BHF (Hydrofluoric acid/Ammonia fluoride solution)
Measurement principle
Absorption spectrometry
Concentration
computation principle
Temperature-compensated multivariate analysis
Measurement range
NH4F: 15.0 to 25.0 %
HF: 0.00 to 3.00 %
H2O: 72.0 to 85.0 %
NH4F: 0.0 to 10.0 %
HF: 0.00 to 3.00 %
H2O: 87.0 to 100.0 %
Reproducibility
(Peak to peak)
NH4F: ±0.3 %
HF: ±0.25 %
H2O: ±1.0 %
NH4F: ±0.3 %
HF: ±0.25 %
H2O: ±1.0 %
Chemical
conditions
Temperature
20 to 30 °C
Flow rate
20 to 60 ml/min.
Pressure
0.10 to 0.20 MPa
Measurement cycle
Approx. 3 seconds minimum
Equipment temperature
20 to 30 °C
Operation panel
1)
Temperature level display:
Ammonia fluoride solution, Hydrofluoric acid, Water
2)
Alarm display (Ammonia fluoride solution, Hydrofluoric acid):
Concentration low-low limit, Concentration low limit,
Concentration high limit, Concentration high-high limit
3)
Alarm value settings
(Ammonia fluoride solution, Hydrofluoric acid):
Concentration low-low limit, Concentration low limit,
Concentration high limit, Concentration high-high limit
Serial input/output
RS-232C
1)
Concentration data:
Ammonia fluoride solution, Hydrofluoric acid, Water
2)
Alarm value settings
(Ammonia fluoride solution, Hydrofluoric acid):
Concentration low-low limit, Concentration low limit,
Concentration high limit, Concentration high-high limit
Parallel input
12 to 30 V DC (photocoupler insulated)
Parallel concentration alarm (ON/OFF)
Parallel output
Maximum current when open collector output is ON:
5 mA
Maximum voltage when open collector output is OFF:
30 V
1)
Alarm output: Ammonia fluoride solution, Hydrofluoric acid:
Concentration low-low limit, Concentration low limit,
Concentration high limit, Concentration high-high limit
2)
Device error (including liquid leakage)
3)
Under measurement
Analog output
4 to 20 mA (2 outputs: NH4F concentration, HF concentration)
Power
24 V DC ±10%, 2 A
Dimensions
205 (W) x 329 (D) x 269 (H) mm
8.1 (W) x 13 (D) x 10.6 (H) in
Mass
Approx. 11 kg
Connection pipe size
For inlet and outlet: Outer diameter 6 mm (inner diameter 4 mm)
Pipe connection
Nippon Pillar Super type
Please consult HORIBA concerning any specifications not listed above.